Offering highly reliable & user-friendly Table Top ETO Sterilizer, Ethylene Oxide Sterilizer, Table Top Flash Autoclaves, Medical Sterilizers, Hospitals Sterilizers, Autoclave Sterilizers, Table Top Steam Sterilizers etc.
We are fastest growing manufacturer and supplier a quality range of Industrial ETO Gas Sterilizers in Ahmedabad, Gujarat, India. A high performing range of eto gas sterilizer is offered to our clients from our end. Ethylene oxide gas sterilization is a method of sterilizing new medical devices and heat sensitive devices. A wide range of delicate devices is sterilized at low temperature. This method is the integral part of a modern cssd. We provide the most effective eto sterilization system that is safe to use and eco-friendly, moreover, these are also customized as per the specifications mentioned by our clients and are fabricated using best quality material and components.
Owing to our highly-advanced infrastructural base and vast knowledge, we are engaged in offering a commendable array of ETO (Ethylene Oxide) Gas Sterilizer. It is primarily used to sterilize Surgical, medical and pharmaceutical products & maize starch products, food and spices products. Offered product is fabricated by our adroit professionals who are adapted with enriched industry-experience in this domain. Apart from this, our customers can avail the entire range at industry leading prices.
Ethylene Oxide (ETO) sterilizer is mainly used to sterilize medical & Surgical and pharmaceutical products & Food and Spices Products, Maize Starch Products.that cannot support conventional high temperature steam sterilization.
The most important parameters in an EtO process are RH, temperature and pressure. For EtO use, it is crucial to control RH and temperature within certain limits. Vacuum (pressure) is pulled to remove air prior to the introduction of EtO making sure the EtO gas permeates the product being sterilized.
A typical EtO sterilization cycle involves several stages and can basically proceed as follows:
Pre conditions: The product is exposed to a warm, humid environment for at least 12 hours (70%RH, 55°C) to ensure the product is at a uniform temperature and humidity.
Exposure: Vacuum is pulled and EtO gas is introduced. The product is exposed for 4-8 hours usually. During the process the RH is kept at approx. 70% and the temperature at 55 °C.
Post conditions: The EtO gas is removed by repeatedly pulling a vacuum and then introducing air into the sterilization chamber until the EtO gas is cleared out (8-12 hours).
It should be noted that there is no standardized cycle for EtO sterilization. Generally there is a tremendous variety in exposure times and gas concentration.
The size of the sterilizers can range from small bench-top sterilizers to large rooms. Because of problems with toxicity and risk of explosion, many companies are choosing to contract out this work rather than perform it themselves. EtO use is therefore becoming very specialized and used by a small number of contract companies. A large part of all medical devices are sterilized by the EtO method.